Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.471
Filtrar
1.
Sci Rep ; 14(1): 8217, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589481

RESUMO

The present study of a novel metal-organic framework containing Fe single atoms doped on electrospun carbon nanofibers (Fe SA-MOF@CNF) based on dispersive micro solid phase extraction (D-µ-SPE) using HPLC-PDA for detection tartrazine in fake saffron samples was designed. The Fe SA-MOF@CNF sorbent was extensively characterized through various techniques including N2 adsorption-desorption isotherms, X-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy. The specific area of surface of the sorbent was 577.384 m2/g. The study variables were optimized via the central composite design (CCD), which included a sorbent mass of 15 mg, a contact time of 6 min, a pH of 7.56, and a tartrazine concentration of 300 ng/ml. Under the optimum condition, the calibration curve of this method was linear in the range of 5-1000 ng/mL, with a correlation coefficient of 0.992. The LOD and LOQ values were ranged 0.38-0.74 and 1.34-2.42 ng/ml, respectively. This approach revealed significant improvements, including high extraction recovery (98.64), recovery rates (98.43-102.72%), and accuracy (RSDs < 0.75 to 3.6%). the enrichment factors were obtained in the range of 80.6-86.4 with preconcentration factor of 22.3. Consequently, the D-µ-SPE method based on synthesized Fe SA-MOF@CNF could be recommended as a sustainable sorbent for detecting tartrazine in saffron samples.


Assuntos
Crocus , Estruturas Metalorgânicas , Tartrazina , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Corantes
2.
Mikrochim Acta ; 191(5): 251, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38589663

RESUMO

Nanocomposite microbeads (average diameter = 10-100 µm) were prepared by a microemulsion-solidification method and applied to the magnetic solid-phase extraction (m-SPE) of fourteen analytes, among pesticides, drugs, and hormones, from human urine samples. The microbeads, perfectly spherical in shape to maximize the surface contact with the analytes, were composed of magnetic nanoparticles dispersed in a polylactic acid (PLA) solid bulk, decorated with multi-walled carbon nanotubes (mPLA@MWCNTs). In particular, PLA was recovered from filters of smoked electronic cigarettes after an adequate cleaning protocol. A complete morphological characterization of the microbeads was performed via Fourier-transform infrared (FTIR) spectroscopy, UV-Vis spectroscopy, thermogravimetric and differential scanning calorimetry analysis (TGA and DSC), scanning electron microscopy (SEM) and X-ray diffraction analysis (XRD). The recovery study of the m-SPE procedure showed yields ≥ 64%, with the exception of 4-chloro-2-methylphenol (57%) at the lowest spike level (3 µg L-1). The method was validated according to the main FDA guidelines for the validation of bioanalytical methods. Using liquid chromatography-tandem mass spectrometry, precision and accuracy were below 11% and 15%, respectively, and detection limits of 0.1-1.8 µg L-1. Linearity was studied in the range of interest 1-15 µg L-1 with determination coefficients greater than 0.99. In light of the obtained results, the nanocomposite microbeads have proved to be a valid and sustainable alternative to traditional sorbents, offering good analytical standards and being synthetized from recycled plastic material. One of the main objectives of the current work is to provide an innovative and optimized procedure for the recycling of a plastic waste, to obtain a regular and reliable microstructure, whose application is here presented in the field of analytical chemistry. The simplicity and greenness of the method endows the procedure with a versatile applicability in different research and industrial fields.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nanocompostos , Nanotubos de Carbono , Humanos , Nanotubos de Carbono/química , Xenobióticos , Microesferas , Poliésteres , Extração em Fase Sólida/métodos , Nanocompostos/química , Fenômenos Magnéticos
3.
J Chromatogr A ; 1721: 464858, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38564928

RESUMO

The establishment of an efficient method for the analysis of drug residues in animal urine facilitates the real-time monitoring of drugs used in the production of animal-derived food. A modified QuEChERS extraction-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established for the determination of 47 banned drug and related chemical residues in livestock urine. The sample was extracted with acetonitrile by converting the acid-base environment. The sample cleanup effects of seven solid phase extraction cartridges and two EMR-Lipid products were compared, and three materials, including graphitized carboxyl multi-walled carbon nanotubes (MWCNTs), PSA, and C18, were selected as QuEChERS adsorbents from 24 materials. All analytes showed good linearity, with correlation coefficients (R2) greater than 0.9936. Low limits of quantification could be obtained, ranging from 0.2 to 5.5 ng/mL. The average recoveries at low, medium, and high spiked levels were in the range of 70.8-114.9 %, with intra-day precision ranging from 2.4 % to 11.2 % and inter-day precision ranging from 4.5 % to 16.1 %. Swine urine and bovine urine samples collected from different farms were effectively analyzed using the developed method, and metronidazole was detected in three swine urine samples.


Assuntos
Resíduos de Drogas , Nanotubos de Carbono , Animais , Bovinos , Suínos , Cromatografia Líquida/métodos , Nanotubos de Carbono/química , Espectrometria de Massas em Tandem/métodos , Gado , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos
4.
J Chromatogr A ; 1721: 464849, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38564930

RESUMO

A novel fluorinated covalent organic polymer @ attapulgite composite (F-COP@ATP) was prepared at room temperature for in-syringe membrane solid-phase extraction (SM-SPE) of domoic acid (DA) in aquatic products. Natural ore ATP has the advantages of low cost, good mechanical strength and abundant hydroxyl group on its surface, and in-situ modified F-COP layer can provide abundant adsorption sites. F-COP@ATP combining the advantages of F-COP and ATP, becomes an ideal adsorbent for DA extracting. Moreover, a high-throughput sample preparation strategy was carried out by using the F-COP@ATP membrane as syringe filter and assembling syringes with a ten-channel injection pump. In addition, the experimental factors were optimized, such as pH of extract, amount of adsorbent, velocity of extraction and desorption, type and volume of desorption solvent. The DA analytical method was established by SM-SPE-HPLC/tandem mass spectrometry. The method had a wide linear range with low limit of detection (0.344 ng/kg) and low limit of quantification (1.14 ng/kg). F-COP@ATP membrane can be reused more than five times. The method realized the analysis of DA in scallop and razor clam samples, which shows its application prospect in practical analysis. This study provided an efficient, low-energy and mild idea for preparing other reusable natural mineral ATP-based composite materials for separation and enrichment, which reduces the experimental cost and is closer to environmental protection and green chemistry to a certain extent.


Assuntos
Polímeros de Fluorcarboneto , Ácido Caínico/análogos & derivados , Compostos de Magnésio , Compostos de Silício , Extração em Fase Sólida , Temperatura , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Trifosfato de Adenosina
5.
Bull Environ Contam Toxicol ; 112(4): 64, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622342

RESUMO

A fast and simple dispersive solid phase extraction method is described for nitrophenols determination in water samples by using gas chromatography-nitrogen phosphorous detector. Firstly, the Poly(amidoamine) grafted Fe3O4 magnetic nanoparticles were synthesized in different generations by successive addition of butyl acrylate and ethylenediamine. After characterization, the prepared dendrimer was utilized as an adsorbent for magnetic solid phase extraction of 2-nitrophenol, 3-nitrophenol, and 4-nitrophenol to benefit large number of surface amine interaction sites. The effects of the different parameters influencing the sample preparation efficiency were investigated. The proposed method showed linearity in the ranges of 0.04-700 and 0.05-700 µg/dm3 for nitrophenols. The obtained limits of detection and quantification under optimized conditions were 0.01-0.02 and 0.04-0.05 µg/dm3, respectively. The relative standard deviations (n = 5) were less than 3.8% (at 10 µg/dm3). Moreover, the calculated enrichment factors were above 200. In addition, the relative recoveries for a spiked river water sample were satisfactory.


Assuntos
Dendrímeros , Poliaminas , Água , Fenômenos Magnéticos , Extração em Fase Sólida/métodos , Nitrofenóis , Limite de Detecção
6.
J Environ Sci (China) ; 142: 33-42, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38527894

RESUMO

Biotoxicity assessment results of environmental waters largely depend on the sample extraction protocols that enrich pollutants to meet the effect-trigger thresholds of bioassays. However, more chemical mixture does not necessarily translate to higher combined biotoxicity. Thus, there is a need to establish the link between chemical extracting efficiency and biotoxicity outcome to standardize extraction methods for biotoxicity assessment of environmental waters. This study compares the performance of five different extraction phases in solid phase extraction (SPE), namely HLB, HLB+Coconut, C18 cartridge, C18 disk and Strata-X, and evaluated their chemical extracting efficiencies and biotoxicity outcomes. We quantitatively assessed cytotoxicity, acute toxicity, genotoxicity, estrogenic activity, and neurotoxicity of the extracts using in vitro bioassays and characterized the chemical extracting efficiencies of the SPE methods through chemical recoveries of 23 model compounds with different polarities and total organic carbon. Using Pareto ranking, we identified HLB+Coconut as the optimal SPE method, which exhibited the highest level of water sample biotoxicity and recovered the most chemicals in water samples. We found that the biotoxicity outcomes of the extracted water samples significantly and positively correlated with the chemical extracting efficiencies of the SPE methods. Moreover, we observed synchronous changing patterns in biotoxicity outcome and chemical extracting efficiencies in response to increasing sample volumes per cartridge (SVPC) during SPE. Our findings underscore that higher chemical extracting efficiency of SPE corresponds to higher biotoxicity outcome of environmental water samples, providing a scientific basis for standardization of SPE methods for adequate assessment of biotoxicities of environmental waters.


Assuntos
Poluentes Ambientais , Poluentes Químicos da Água , Águas Residuárias/toxicidade , Água/química , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/análise
7.
Anal Chem ; 96(11): 4639-4646, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501258

RESUMO

Multicomponent reactions offer efficient and environmentally friendly strategies for preparing monoliths suitable for applications in analytical chemistry. In the described study, a multicomponent reaction was utilized for the one-pot miniaturized preparation of a poly(propargyl amine) polymer inside commercial silica-lined PEEK tubing. The reaction involved only small amounts of reagents and was characterized by atom economy. The resulting monolithic column was incorporated into an autosampler system for the online extraction and cleanup of ß-estradiol from human serum. Sample pretreatment was simplified to a simple dilution with methanol and centrifugation to remove proteins. The resulting platform included LC-MS analysis in multiple reaction monitoring for quantitative analysis of ß-estradiol. The method was validated in serum, demonstrating practical applicability for the monitoring of fertile women. Recoveries were above 94%, and LOD and LOQ values at 0.008 and 0.18 ng mL-1, respectively. The developed platform proved to be competitive with previous methods for solid-phase microextraction of ß-estradiol in serum, with comparable recovery and sensitivity but with the advantage of nearly complete automation. The environmental impact of the process was evaluated as acceptable due to the miniaturization of the monolith synthesis and the automation of extraction. The drawback associated with the LC-MS technique can be reduced by the inclusion of additional analytes in a single investigation. The work demonstrates that multicomponent reactions are versatile, economical, and possibly a green methodology for producing reversed-phase and mixed-mode sorbents, enabling miniaturization of the entire analytical procedure from the preparation of extraction sorbents to analysis.


Assuntos
60705 , Espectrometria de Massas em Tandem , Humanos , Feminino , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Estradiol , Microextração em Fase Sólida/métodos , Extração em Fase Sólida/métodos
8.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542125

RESUMO

In recent years, there has been a growing interest in plant pigments as readily available nutraceuticals. Photosynthetic pigments, specifically chlorophylls and carotenoids, renowned for their non-toxic antioxidant properties, are increasingly finding applications beyond their health-promoting attributes. Consequently, there is an ongoing need for cost-effective methods of isolation. This study employs a co-precipitation method to synthesize magnetic iron oxide nanoparticles. Scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS) confirms that an aqueous environment and oxidizing conditions yield nanosized iron oxide with particle sizes ranging from 80 to 140 nm. X-ray photoelectron spectroscopy (XPS) spectra indicate the presence of hydrous iron oxide FeO(OH) on the surface of the nanosized iron oxide. The Brunauer-Emmett-Teller (BET) surface area of obtained nanomaterial was 151.4 m2 g-1, with total pore volumes of pores 0.25 cm3 g-1 STP. The material, designated as iron oxide nanoparticles (IONPs), serves as an adsorbent for magnetic solid phase extraction (MSPE) and isolation of photosynthetic pigments (chlorophyll a, lutein) from extracts of higher green plants (Mentha piperita L., Urtica dioica L.). Sorption of chlorophyll a onto the nanoparticles is confirmed using UV-vis spectroscopy, Fourier transform infrared photoacoustic spectroscopy (FT-IR/PAS), and high-performance liquid chromatography (HPLC). Selective sorption of chlorophyll a requires a minimum of 3 g of IONPs per 12 mg of chlorophyll a, with acetone as the solvent, and is dependent on a storage time of 48 h. Extended contact time of IONPs with the acetone extract, i.e., 72 h, ensures the elimination of remaining components except lutein, with a spectral purity of 98%, recovered with over 90% efficiency. The mechanism of chlorophyll removal using IONPs relies on the interaction of the pigment's carbonyl (C=O) groups with the adsorbent surface hydroxyl (-OH) groups. Based on molecular dynamics (MD) simulations, it has been proven that the selective adsorption of pigments is also influenced by more favorable dispersion interactions between acetone and chlorophyll in comparison with other solutes. An aqueous environment significantly promotes the removal of pigments; however, it results in a complete loss of selectivity.


Assuntos
Compostos Férricos , Luteína , Extratos Vegetais , Extratos Vegetais/química , Clorofila A , Clorofila , Espectroscopia de Infravermelho com Transformada de Fourier , Acetona , Água , Adsorção , Extração em Fase Sólida/métodos , Nanopartículas Magnéticas de Óxido de Ferro , Fenômenos Magnéticos
9.
J Chromatogr A ; 1720: 464800, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38458139

RESUMO

Speciation of Se(IV) and Se(VI) is essential due to their significant differences in reactivity, toxicity and bioavailability. Efficient extraction is the pivotal step in the quantification of inorganic selenium species. In this work, a new magnetic nano-composite (MNC) containing boronic acid group and aminated multwalled carbon nanotubes was facilely fabricated by means of one-pot hydrothermal strategy. The prepared MNC contained abundant functional groups and satisfactory magnetic saturation value. Combining with magnetic solid phase extraction (MSPE) format, the MNC displayed satisfactory capture performance towards the complex formed by the coordination of Se(IV) and o-phenylenediamine (OPA). Adsorption isotherm and adsorption kinetics were studied in detail to investigate the adsorption procedure of Se(IV)/OPA complex on MNC. Under the optimal preparation conditions of MNC and extraction parameters, the MNC/MSPE was connected with HPLC equipped with a diode array detector (DAD) to quantify trace Se(IV) and Se(VI) species in water and milk samples. Se(VI) was reduced to Se(IV) and then the total inorganic Se was quantified by the developed method. Subtraction method was used to measure the concentration of Se(VI). The achieved limits of detection were in the ranges of 0.0082-0.013 µg/L and 0.041-0.13 µg/kg for water and milk samples, respectively. Recoveries in actual samples spiked with different amounts of analytes varied from 81.0 % and 117 %, and the RSDs for repeatability varied from 1.0 % to 10 %. In comparison with existing studies based on MSPE, the established method presents some merits such as greenness in the preparation of magnetic adsorbent, rapid extraction procedure, low cost and satisfactory sensitivity in the speciation of inorganic Se species.


Assuntos
Nanotubos de Carbono , Água , Animais , Água/química , Leite , Magnetismo , Fenômenos Magnéticos , Extração em Fase Sólida/métodos
10.
J Chromatogr A ; 1720: 464785, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38458141

RESUMO

Amphiphilic materials can be used for sample preparation of chromatography or mass spectrometry. Amphiphilic materials with magnetic properties in combination with magnetic suction devices allow for automated sample preparation. However, conventional synthesis methods are cumbersome and not suitable for the mass production of the material. In this study, a micro-suspension polymerization method was developed to synthesize magnetic amphiphilic resin microspheres (MARMs), providing new ideas for the preparation of amphiphilic microspheres. MARMs with particle sizes ranging from 3 to 6 µm were successfully prepared, with BET surface area up to 653.2 m2/g. A magnetic solid-phase extraction method based on MARM-5 was developed for the extraction of four glucocorticoids including Cortisone, Hydrocortisone, Cortodoxone, and Corticosterone. This method had a very short adsorption time of 0.5 min and a total extraction time of only 13 min. The limit of detection for the four glucocorticoids ranged from 0.22 to 0.82 ng/L. There was a good linear relationship between sample concentration and peak area in the range of 25∼500 ng/L. Relative recovery of 98 %∼108 % and internal standard normalized matrix effect factors of 95∼114 % were obtained, and the relative standard deviation was between 2.3 % and 6.3 %. The MARMs would be used as excellent solid extraction material for glucocorticoids.


Assuntos
Glucocorticoides , 60705 , Microesferas , Polimerização , Fenômenos Magnéticos , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão
11.
Bull Environ Contam Toxicol ; 112(3): 48, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459992

RESUMO

This study aimed on the development of a SPE-UHPLC-MS/MS method for the simultaneous determination of pesticide residues in drinking water samples. A chemometric approach was applied to optimize the efficiency of the SPE pretreatment procedure. This study involved (i) the application of a Full Factorial Design for the screening of the significant factors, (ii) the application of a Central Composite Design for the determination of the optimal conditions and (iii) the evaluation and validation of the significance of the statistically proposed models. Oasis HLB cartridges were used for the extraction. The optimum sample volume was 300 mL and the elution solvent 3 mL of the mixture of methanol:ethylacetate 70:30 v/v. The method was validated according to the international guidelines. Recoveries were ranged from 63 to 116% and the detection limits were between 0.1 and 1.5 pg mL- 1. The validated method could be used in routine analysis for pesticides screening.


Assuntos
Praguicidas , Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Quimiometria , Extração em Fase Sólida/métodos , Água
12.
J Chromatogr A ; 1720: 464807, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38461769

RESUMO

A method based on novel restricted access materials (RAMs) for the determination of neonicotinoid pesticides in Goji samples using offline and online solid phase extraction (SPE) coupled with high-performance liquid chromatography (LC). RAMs were synthesized using poly(chloromethylstyrene-co-divinylbenzene) (PVBC/DVB) microspheres as substrate, styrene (St) and n-vinylpyrrolidone (NVP) were first copolymerized on the interior to construct adsorption sites, and sulfobetaine methacrylate (SBMA) was then polymerized on the exterior to form exclusion sites via two-step surface initiated-atom transfer polymerization. The prepared PVBC/DVB@poly(St-co-NVP)@poly(SBMA) RAMs could efficiently extract neonicotinoid pesticides and automatically exclude proteins. Under the optimized conditions, the developed methods of offline (magnetic SPE and SPE column) and online extraction coupled with LC both using PVBC/DVB@poly(St-co-NVP)@poly(SBMA) RAMs as the extractant, exhibit a wide linearity, low limits of detection and limit of quantification and good inter-day and intra-day precision with satisfactory recoveries. Among these methods, online extraction coupled with LC based on novel RAMs exhibits clear advantages for the determination of neonicotinoid pesticides in Goji samples has clear advantages, such as simple operation by direct injection, short extraction times, and high accuracy with less human error.


Assuntos
Praguicidas , Polímeros , Humanos , Polímeros/química , Praguicidas/análise , Adsorção , Extração em Fase Sólida/métodos , Estireno , Cromatografia Líquida de Alta Pressão/métodos
13.
Anal Methods ; 16(13): 1870-1879, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38465391

RESUMO

This paper presents a study on the application of magnetic biochars derived from three distinct biomass sources: almond (AMBC), walnut (WMBC), and peanut (PMBC) shells for magnetic solid-phase extraction (MSPE) of naproxen, a non-steroidal anti-inflammatory drug, from human saliva prior to LC-MS analysis. The three magnetic biochars were synthesized and characterized through IR, XRD, SEM, and EDX analyses. This work explored the factors influencing extraction efficiency using these three bioadsorbents through experimental design. The results obtained revealed that magnetic biochar derived from almond shells demonstrated outstanding performance in terms of naproxen extraction, achieving an impressive yield of 100.2%. This remarkable efficiency was achieved by optimizing parameters, including a 12-minute extraction time, a 3.5 mL elution volume, a 10 mg adsorbent mass, and a 4-minute elution time. Consequently, this study established almond shell as a low-cost, environmentally friendly, and efficient magnetic biochar for extracting naproxen from human saliva. This superior performance was made possible due to the abundant lignocellulosic potential inherent in almond shell structures, surpassing that of the other two biochars. The combination of magnetic extraction with LC-MS demonstrates good linearity, with an R2 value equal to 0.9987. The limits of detection (LOD) and quantification (LOQ) are 0.013 and 0.047 µg L-1, respectively.


Assuntos
Carvão Vegetal , Naproxeno , Saliva , Humanos , Naproxeno/química , Biomassa , Extração em Fase Sólida/métodos , Fenômenos Magnéticos
14.
Anal Methods ; 16(13): 1880-1886, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38469698

RESUMO

The study of ibuprofen (IBU) preconcentration was carried out making use of a homemade column for solid-phase extraction (SPE), using vermiculite (VT) or organo-vermiculites (OVTs) as sorbent phases. Aqueous samples (50.0 mL) percolated the column and IBU was sorbed onto the VT or OVT and then desorbed using acetonitrile. Employing this SPE system and OVT, calibration curves were generated for IBU, by spectrophotometric quantification using the α-naphthylamine method. R2 values higher than 0.9950 and LOD between 12 and 18 µg L-1 were observed, for real enrichment factors of 21 and 31, by using OVTs. The analytical protocol was applied to three water samples, which were spiked with IBU solutions to evaluate the precision and accuracy of the method. Recoveries between 77 and 110% at three different IBU concentrations and RSD lower than 18% were observed, even by using the spectrophotometric method. The protocol developed in this study demonstrated that the OVT was appropriate to work as a preconcentration phase for IBU determination in water samples.


Assuntos
Ibuprofeno , Água , Silicatos de Alumínio , Extração em Fase Sólida/métodos
15.
J Chromatogr A ; 1720: 464809, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38490141

RESUMO

An ultrafast, efficient, and eco-friendly method combining magnetic solid phase extraction and capillary electrophoresis with diode array detection have been developed to determine ractopamine residues in food samples. A restricted access material based on magnetic and mesoporous molecularly imprinted polymer has been properly synthesized and characterized, demonstrating excellent selectivity and high adsorbent capacity. Short-end injection capillary electrophoresis method was optimized: 75 mM triethylamine pH 7 as BGE, -20 kV, 50 mbar by hydrodynamic injection during 8 s, and capillary temperature at 25 °C; reaching ultrafast ractopamine analysis (∼0.6 min) with good peak asymmetry, and free from interfering and/or baseline noise. After sample preparation optimization, the conditions were: 1000 µL of sample at pH 6, 20 mg of adsorbent, stirring time of 120 s, 250 µL of ultrapure water as washing solvent, 1000 µL of methanol: acetic acid (7: 3, v/v) as eluent, and the adsorbent can be reused four times. In these conditions, the analytical method showed recoveries around to 100 %, linearity ranged from 9.74 to 974.0 µg kg-1, correlation coefficient (r) ≥ 0,99 in addition to adequate precision, accuracy, and robustness. After proper validation, the method was successfully applied in the analysis ractopamine residues in bovine milk and bovine and porcine muscle.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Fenetilaminas , Animais , Suínos , Extração em Fase Sólida/métodos , Eletroforese Capilar/métodos , Fenômenos Magnéticos , Impressão Molecular/métodos , Cromatografia Líquida de Alta Pressão/métodos
16.
J Chromatogr A ; 1720: 464814, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38490140

RESUMO

A magnetic polyimide (PI) nanocomposite has been synthesized by phase inversion of PI and simultaneous encapsulation of Fe3O4 nanoparticles. The Fe3O4/PI nanocomposite was characterized by a variety of characterization techniques, including infrared spectroscopy, scanning electron microscopy, transmission electron microscopy, nitrogen adsorption-desorption isotherms, and vibrating sample magnetometry. The results showed that the prepared nanocomposite had a homogeneous structure, adequate specific surface area (76.1 m2/g) and high saturation magnetization (42.9 emu/g). Using parabens as model analytes, the performance of the Fe3O4/PI nanocomposite as an adsorbent for magnetic solid-phase extraction (MSPE) was evaluated. The extracted parabens were desorbed and determined by gas chromatography-mass spectrometry (GC-MS). The parameters affecting the extraction and desorption efficiency of parabens were optimized. Under the optimal conditions, the developed MSPE/GC-MS method was successfully applied to the determination of parabens in cooking wine. The MSPE/GC-MS method exhibited broad linearity (0.2-100 µg/L), low detection limits (0.04-0.05 µg/L), and satisfactory extraction recoveries (79.2 %-113.3 %) with relative standard deviations (RSDs) ranging from 0.7 % to 10.4 %. For real cooking wine samples, the spiked recoveries ranged from 91.7 % to 118.7 % with RSDs of 1.0 %-11.2 %. The results demonstrated that the Fe3O4/PI nanocomposite was an effective adsorbent, and this work provides a novel reference for the easy preparation of magnetic adsorbent materials.


Assuntos
Nanocompostos , Vinho , Cromatografia Gasosa-Espectrometria de Massas , Parabenos , Adsorção , Fenômenos Magnéticos , Extração em Fase Sólida/métodos , Nanocompostos/química , Limite de Detecção , Cromatografia Líquida de Alta Pressão/métodos
17.
Artigo em Inglês | MEDLINE | ID: mdl-38520897

RESUMO

Extraction of vitamin D, including its hydroxylated and esterified metabolites, from soft tissues such as the liver is challenging due to the lipophilic character of matrix and analytes that are expected in very low concentration levels. In this study, we aimed at the optimization of two-step extraction using solid-liquid extraction as the first step, followed by solid-phase extraction. Various solvents, including ethanol, acetonitrile, methanol, acetone, heptane, and heptane with isopropanol, were investigated to isolate vitamin D compounds from liver tissue in the first step. Acetone was finally selected as the most suitable solvent for the solid-liquid extraction, with the highest recovery in the range of 67 - 98% for polar hydroxylated forms and 3 - 28% for lipophilic vitamin D and esters. Two solid phase extraction (SPE) based on the (i) "bind and elute strategy" and (ii) "removal strategy" using hydrophilic-lipophilic balanced SPE sorbent were optimized as a proceeding step for acetone extracts to increase the method selectivity. Finally, two optimized methods, combining solid-liquid extraction and individual SPE strategy, were examined in terms of sensitivity, recovery, matrix effect, accuracy, and precision. The limits of quantification were in the range of 1 - 10 ng/mL and 3 - 20 ng/mL analyzed by ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography hyphenated a with tandem mass spectrometer, respectively. The absolute recovery determined for the "bind and elute strategy" protocol was in the range of 3 - 24 %. Nevertheless, this method was free of matrix effects, which were determined to be in the 73 - 120 % range. On the contrary, the "removal strategy" approach provided higher recovery values for all compounds (47 - 123 %), but the results for nonpolar vitamin D and esters were strongly affected by signal suppression (matrix effects 3 - 51 %). Both methods fulfilled the criteria for accuracy and precision requested by the European Medicine Agency Guideline on Bioanalysis. "Removal strategy" SPE with decreased manual intervention and lower solvent consumption was finally applied to mouse liver tissue to determine vitamin D and its hydroxylated and esterified metabolites for the first time. The results, i.e., vitamin D esters detected in liver tissue, supported the notion that esters of vitamin D can be stored in lipophilic tissues to release vitamin D.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Animais , Camundongos , Espectrometria de Massas em Tandem/métodos , Acetona , Cromatografia Líquida de Alta Pressão/métodos , Solventes , Vitaminas , Fígado , Heptanos , Extração em Fase Sólida/métodos
18.
Artigo em Inglês | MEDLINE | ID: mdl-38522130

RESUMO

Accurate monitoring of UV-filters exposure levels in human plasma is a challenge because of the significant differences in the physicochemical properties of UV-filters, as well as the matrix effect caused by abundant proteins and phospholipids in plasma. Therefore, an effective and rapid method for simultaneous determination of 14 UV-filters in human plasma using protein precipitation-solid phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. Acetonitrile with 0.1 % formic acid and 10 % isopropanol (v/v) were used as mobile phases. A gradient elution on an ACQUITY UPLC BEH-C18 column at 30 °C and 0.3 mL/min flow rate was applied for separation. The electrospray ionization positive or negative modes were selected to determine the corresponding analyte to increase selectivity and sensitivity. Results showed that acetonitrile-tetrahydrofuran (v/v, 8:2) as the extraction solvent can effectively precipitate protein in plasma and improve the solubility of UV-filters. The HybridSPE cartridge improved the removal efficiency of phospholipids, while 1 mL of methanol elution increased the extraction recoveries of targets. Fourteen UV-filters achieved good linearities, low detection limits (0.050 to 0.10 µg/L) and quantification limits (0.10 to 1.0 µg/L). Method accuracy and precision, extraction recoveries, and storage stabilities of all analytes met the criterion of 80-120 %. Moreover, this method was successfully applied for the determination of UV-filters in plasma randomly collected from adults. Nine of 14 UV-filters were determined and their concentrations were distributed widely, suggesting a big variation of individual UV-filters exposure.


Assuntos
Fosfolipídeos , Espectrometria de Massas em Tandem , Adulto , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Fosfolipídeos/química , 60705 , Acetonitrilas , Extração em Fase Sólida/métodos
19.
J Chromatogr A ; 1721: 464826, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38522407

RESUMO

A new approach to extracting substances from a spot on a chromatographic plate for subsequent liquid chromatography-mass spectrometry analysis is described. This method involves extraction in a solid phase (an adsorbent layer of a chromatographic plate) - a liquid system using a simple device. For a single extraction of six selected coccidiostats from the adsorbent layer on the chromatographic plate with silica gel, 50 µL of methanol was used for 5 min. The data from the extraction experiments and liquid chromatography-mass spectrometry measurements demonstrated a good correlation between the ratio of the peak areas of the coccidiostats to the internal standard and the concentration of the substances in the range of two orders of magnitude. The coefficients of determination for the mentioned correlations range from 0.962 to 0.999. Moreover, the repeatability and reproducibility, expressed as the percentage values of relative standard deviation, do not exceed 7.5 % for any of the coccidiostats.


Assuntos
Coccidiostáticos , Coccidiostáticos/análise , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Metanol , Extração em Fase Sólida/métodos
20.
J Chromatogr A ; 1721: 464844, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38547678

RESUMO

The highly conjugated and hydrophobic characteristics of microporous organic networks (MONs) have largely impeded their broad applications in sample pretreatment especially for the polar or ionic analytes. In this work, a novel uniform hollow shaped sulfonate group functionalized MON (H-MON-SO3H-2) was synthesized via the sacrificial template method for the efficient solid phase extraction (SPE) of sulfonamides (SAs) from environmental water, milk, and honey samples prior to HPLC analysis. H-MON-SO3H-2 exhibited large specific surface area, penetrable space, good stability, and numerous hydrogen bonding, electrostatic, hydrophobic and π-π interaction sites, allowing sensitive SPE of SAs with wide linear range (0.150-1000 µg L-1), low limit of detection (0.045-0.188 µg L-1), good precisions (intra-day and inter-day RSD < 7.3%, n = 5), large enrichment factors (95.7-98.5), high adsorption capacities (250.4-545.0 mg g-1), and satisfactory reusability (more than 80 times). Moreover, the established method was successfully applied to extract SAs from spiked samples with the recoveries of 86.1-104.3%. This work demonstrated the great potential of H-MON-SO3H-2 in the efficient SPE of trace SAs in complex environmental water and food samples and revealed the prospect of hollow MONs in sample pretreatment.


Assuntos
Antibacterianos , Mel , Antibacterianos/análise , Mel/análise , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Sulfanilamida/análise , Água/química , Sulfonamidas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...